Spectrometer Manufacturer,Supplier and Exporter in India
Product Code : EL-PLE-10835
Quick Answer: The Spectrometer is a cast metal spectrometer with plated fittings, a 150 mm diameter circular scale read by a double ended vernier to 1 minute of arc, a collimator and a telescope with 178 mm focus achromatic objectives (25 mm clear aperture), an 8x Ramsden eyepiece and a prism table, used for optics experiments with prisms.
Last updated: October 2026
Key Features
- Heavy cast metal body with plated fittings
- 150 mm diameter circle scale with protective plastic shield; double ended vernier reads to 1 minute of arc
- Collimator with a 178 mm focus achromatic objective, 25 mm clear aperture and an adjustable slit 7 mm long
- Telescope with a 178 mm focus achromatic objective, 25 mm clear aperture, 8x Ramsden eyepiece and glass cross line graticule
- Rack and pinion focusing on both telescope and collimator
- Prism table marked with lines to help place the prism relative to the levelling screws
Technical Specifications
| Specification | Value |
|---|---|
| Construction | Heavy cast metal, plated fittings |
| Scale | 150 mm diameter circle with protective plastic shield |
| Vernier | Double ended, reads to 1 minute of arc |
| Collimator objective | 178 mm focus achromatic, 25 mm clear aperture |
| Collimator slit | Unilaterally adjustable, 7 mm long |
| Telescope objective | 178 mm focus achromatic, 25 mm clear aperture |
| Eyepiece | 8x Ramsden, with glass cross line graticule |
| Focusing | Rack and pinion, telescope and collimator |
| Prism table | Marked with lines for placing the prism relative to the levelling screws |
About This Product
A spectrometer is used to measure angles accurately in optics experiments. Light from the slit passes through the collimator as a parallel beam and meets the prism on the table. The telescope is then turned to find the refracted or dispersed rays, and the circular scale with its vernier gives the angle. In school and college physics labs it is used to find the angle of a prism, the angle of minimum deviation and the refractive index, and to observe spectra.
Frequently Asked Questions
Q1. How finely does the Spectrometer read angles?
The double ended vernier reads to 1 minute of arc on a 150 mm diameter circular scale.
Q2. What optics are fitted?
The collimator and telescope each have a 178 mm focus achromatic objective with a 25 mm clear aperture, and the telescope has an 8x Ramsden eyepiece with a glass cross line graticule.
Related: Physics Lab Equipment, Prism Glass, Prism Acrylic, Ray Box, Telescope.