EDDy CURENT Manufacturer,Supplier and Exporter in India
Product Code : EL-EE-12386
Quick Answer: The Eddy Current instrument is a digital defect-detection unit that can detect defects from 0.1 mm in depth and from 0.002 mm in opening. Its operating frequency is set between 50 Hz and 12 MHz, with a generator output of 0.5 V to 6 V (double amplitude).
Last updated: October 2026
Key Features
- Detects defects from 0.1 mm depth and 0.002 mm opening
- Operating frequency set from 50 Hz to 12 MHz
- Generator output voltage (double amplitude) 0.5 V to 6 V
- Adjustable gain range 30 dB and preamplifier range 40 dB
- Phase signal rotation 0° to 360° in steps of 0.1°, 1° and 10°
- Sampling frequency up to 6 kHz; 5 digital filter types
Technical Specifications
| Specification | Value |
|---|---|
| Defect detection, depth | From 0.1 mm |
| Defect detection, opening | From 0.002 mm |
| Operating frequency | 50 Hz to 12 MHz |
| Generator output voltage (double amplitude) | 0.5 V to 6 V |
| Gain range | 30 dB |
| Preamplifier range | 40 dB |
| Phase signal rotation | 0° to 360°, in steps of 0.1°, 1° and 10° |
| Sampling frequency | Up to 6 kHz |
| Digital filters | 5 types: lowpass, highpass, bandpass, differential, averaging |
About This Product
Eddy current testing is a non-destructive method in which an alternating current in a coil induces eddy currents in a conductive part. A crack or other defect changes the flow of these currents, and the change is seen as a shift in amplitude and phase of the signal on the instrument display. The operating frequency, gain and phase rotation are adjusted to separate defect signals from noise, and digital filters help clean the signal. In NDT training the method is used to show surface and near-surface flaw detection in metals. The Eddy Current can be supplied for export orders from Serbia, Colombia, Lebanon, Namibia, Paraguay and Qatar.
Frequently Asked Questions
Q1. What size of defect can the Eddy Current instrument detect?
It can detect defects from 0.1 mm in depth and from 0.002 mm in opening.
Q2. What frequency range does it cover?
The operating frequency can be set from 50 Hz to 12 MHz, with sampling up to 6 kHz.
Q3. Which digital filters are available?
It has 5 digital filter types: lowpass, highpass, bandpass, differential and averaging.
Related: Engineering Equipment, Ultrasonic Testing, Magnetic Particle NDT Tester, Radiographic Tester, Automated Micro Hardness Testing Machine.