Fire Alarm Trainer Manufacturer,Supplier and Exporter in India
Product Code : EL-EE-12397
Quick Answer: The Fire Alarm Trainer is a bench-mounted unit with a two-zone fire alarm system, fitted with a visible smoke detector, an ionization smoke detector, a manual call point, a fixed temperature detector and a rate of rise temperature detector, plus visual and audio alarms. Its control unit has 6 switched faults and accepts up to 6 external alarm and 15 detector circuits wired by students.
Last updated: October 2026
Key Features
- Bench-mounted two-zone fire alarm system
- First zone: visible smoke detector, ionization smoke detector and manual call point
- Second zone: fixed temperature and rate of rise temperature detectors
- Visual and audio alarms
- Detectors in fire retardant cases, each activated separately with the accessories supplied
- Control unit with 6 switched faults, up to 6 external alarm and 15 detector circuits
Technical Specifications
| Specification | Value |
|---|---|
| Type | Bench-mounted two-zone fire alarm system |
| First zone | Visible smoke detector, ionization smoke detector, manual call point |
| Second zone | Fixed temperature detector, rate of rise temperature detector |
| Alarms | Visual and audio |
| Detector housing | Fire retardant cases |
| Switched faults | 6 |
| External alarm circuits | Up to 6 |
| Detector circuits | Up to 15, wired by students |
About This Product
A fire alarm system detects smoke or heat and warns people to leave a building. Smoke detectors respond to smoke particles, while fixed temperature and rate of rise detectors respond to a set temperature or a quick rise in temperature, and a manual call point lets a person raise the alarm. On the trainer, students can trigger each detector, watch the alarms respond, use the switched faults to simulate problems, and wire their own alarm and detector circuits. This teaches how zones, detectors and alarms work together. The Fire Alarm Trainer can be supplied for export orders from South Sudan, Republic of the Congo, Ghana, Barbados and Paraguay.
Frequently Asked Questions
Q1. How many zones does the Fire Alarm Trainer have?
It has two zones. One has a visible smoke detector, an ionization smoke detector and a manual call point; the other has a fixed temperature and a rate of rise temperature detector.
Q2. How many circuits can students wire?
The control unit accepts up to 6 external alarm and 15 detector circuits wired by students, and has 6 switched faults.
Q3. How are the detectors activated?
Each detector is housed in a fire retardant case and may be activated separately in a controlled fashion with the accessories supplied.
Related: Engineering Equipment, Security Alarm Trainer, Fire Extinguisher, Electrical Installation Trainer, Experiment Case on Protective Measures and Safety.