Open Care Warmer - Resuscitation Unit Manufacturer,Supplier and Exporter in India
Product Code : EL-ICFMLE-12790
Quick Answer: The Open Care Warmer - Resuscitation Unit is an infant warmer with a 600 W quartz encapsulated heater and parabolic reflector, separate displays for set and skin temperatures, a 25°C to 40°C range and a thermistor probe.
Last updated: October 2026
Key Features
- Quartz encapsulated 600 W heater with parabolic reflector
- Separate displays for set and skin temperatures
- Thermistor based interchangeable probe
- Automatic heater cut-off at 40°C
- Alarms for high and low temperature, probe failure and system failure
- Microprocessor based system with periodic self-diagnosis
Technical Specifications
| Specification | Value |
|---|---|
| Heater element | Quartz encapsulated 600 W heater with parabolic reflector (ceramic optional) |
| Heater output | 0 to 100%, 20% increment |
| Probe | Thermistor based, interchangeable; calibration not required |
| Temperature range | 25°C to 40°C |
| Accuracy | ± 0.2°C |
| Resolution | 0.1°C |
| Power | 180 V to 250 V at 50 Hz, 700 W |
| Over temperature protection | Automatic heater cut-off at 40°C |
| Heater module swivel | ± 90° |
| Mattress size | 800 x 500 mm, 2 inches thick |
| Dimensions (H x W x L) | 77 x 30 x 36 inches |
| Weight | 70 kg without accessories |
| Coating | Epoxy powder coated body |
About This Product
An open care warmer is a radiant heater over an open infant bed, used where staff need open access to the infant, for example during resuscitation. The heater is a quartz element with a parabolic reflector, and the infant temperature and set temperature are shown on separate displays. A halogen examination lamp lights the baby, and the heater module can swivel. Alarms signal temperature differences, probe failure and system failure.
Frequently Asked Questions
Q1. What temperature range does the warmer cover?
The range is 25°C to 40°C, with an accuracy of ± 0.2°C and a resolution of 0.1°C.
Q2. Which heater does it use?
It uses a quartz encapsulated 600 W heater with a parabolic reflector, and a ceramic heater is optional.
Q3. Which alarms does it have?
Alarms are listed for high temperature, low temperature, temperature probe failure and system failure, with key lock and alarm mute facilities.
Related: Infant Care Equipment, Neonatal Radiant Warmer, Infant Radiant Warmer, Resuscitation Unit, Infant Baby Incubator.
For a quotation on the Open Care Warmer - Resuscitation Unit, contact School Lab Equipment India.